Understand the key points and potential issues of RO backwashing by reviewing the fundamental definition and operational process of reverse osmosis membrane backwashing.
Differences Between Ultrafiltration Membrane Backwashing and Reverse Osmosis Membrane Backwashing
Regarding RO membrane backwashing (reverse flushing or cleaning), there isn't much disagreement, and there's generally consensus on the matter. However, when it comes to the issues arising from RO membrane system backwashing, I feel it's necessary to revisit the fundamental concepts of RO membrane backwashing today and venture a guess as to why the aforementioned misconceptions may have spread so widely.
First, as usual, let's understand the key points and potential issues of RO backwashing by reviewing the fundamental definition and operational process of reverse osmosis membrane backwashing.

I. Reverse Osmosis Membrane Backwashing (Primarily sourced from Hydranautics Technical Manual)
(1) Basic Definition of Reverse Osmosis Membrane Backwashing
Forward Cleaning: Historically, CIP systems were designed with cleaning solution entering at the feed end of the pressure vessel, passing through the membrane elements, and exiting at the concentrate end. This flow direction mirrors normal RO system operation and is a common, effective cleaning method. Reverse Cleaning: However, reverse cleaning has proven beneficial in certain scenarios. When severe biological, colloidal, or particulate fouling occurs, contaminants can heavily accumulate on the first membrane element at the feed end. Breaking up these contaminants and flushing them through all membrane elements within the pressure vessel is extremely difficult. In most cases, however, reversing the cleaning solution flow (entering from the concentrate side and exiting from the feed side, note that the feed and concentrate labels in Figure 2 are reversed) facilitates easier removal of contaminants.
(2) Precautions for Reverse Osmosis Membrane Backwashing
① Prioritize Removal of End-Stage Scaling
During backwashing, insoluble salt scaling at the membrane system's end must be addressed first. The edges of these salt crystals are extremely sharp. If backwashing proceeds without prior removal, these crystals may directly damage the membrane surface, causing more severe harm than conventional (forward) cleaning. Therefore, when scaling exists in the system, conventional (forward) cleaning is typically performed first to prioritize removing end-of-line scaling.
② Setting Cleaning Flow Rate Limits
During conventional forward cleaning, end-of-line reverse osmosis membrane elements are protected by thrust rings, preventing compression deformation. However, during backwashing, the first membrane element lacks thrust ring protection. Therefore, we recommend limiting the cleaning flow rate during backwashing. For 8-inch membrane elements, the conventional cleaning flow rate is 136-182 L/min. We recommend limiting the backwash flow rate to 2/3 of the conventional cleaning flow rate, i.e., 91-121 L/min. If the pressure differential is very high and contamination is severe, reduce the cleaning flow rate to 1/3 (45-61 L/min) to minimize the risk of membrane element deformation. For membrane elements using 34mil inlet screens, the cleaning flow rate is slightly higher than for conventional membrane elements (see table below). Begin cleaning at a lower flow rate, then gradually increase based on the actual pressure differential. Only when contaminants are removed and the pressure differential decreases should the flow rate be slowly increased. Finally, perform backwashing at the standard flow rate as the last step.
Caution: Never clean membrane elements from the product water side. This creates back pressure on the membrane elements, causing irreversible damage.
③ Additional Considerations
Not all RO membrane systems can be easily retrofitted for reverse flushing. The optimal solution is to design the system during construction to allow flushing from any direction. Note that bidirectional flushing is required; systems should not be designed solely for reverse flushing. The second option is to design the system for reverse (concentrate-to-feed) flushing. While less effective than reverse flushing, this helps remove contaminants from the front end of the RO system. The third approach involves removing the heavily fouled first membrane, disassembling the concentrate seal, reversing the membrane orientation, and reinstalling the concentrate seal at the opposite end (the former concentrate side). This facilitates easier removal of severe fouling through conventional forward cleaning. In many cases, this operational method also aids in contaminant removal. The concentration, pH, temperature, and other parameters for the backwash solution remain consistent with conventional cleaning.
Summary: Reviewing the fundamental principles of reverse osmosis membrane backwashing reveals that under specific conditions (when severe biological, colloidal, or particulate fouling causes significant contaminant accumulation on the first membrane at the feed end), combining reverse osmosis membrane backwashing with conventional forward flushing can indeed improve membrane element performance. Of course, related designs and processes must strictly adhere to the aforementioned specifications.
Particular attention must be paid to the statements regarding “back pressure” in the preceding content: Under no circumstances should membrane elements be cleaned from the product water side, as this creates back pressure that causes irreversible damage to the membrane elements. Why do many people believe reverse osmosis membrane backwashing generates back pressure? It is likely because they interpret reverse osmosis membrane backwashing as being similar to ultrafiltration membrane backwashing (a bold conjecture). Ultrafiltration membrane backwashing precisely uses the product water outlet as the backwash inlet.
Among these points, we must pay particular attention to the statements regarding “back pressure”: Under no circumstances should membrane elements be cleaned from the product water side, as this will create back pressure on the membrane elements, causing irreversible damage. Why do many people believe that backwashing reverse osmosis membranes generates back pressure? Because many interpret reverse osmosis membrane backwashing as being similar to ultrafiltration membrane backwashing (a bold guess). Ultrafiltration membrane backwashing precisely uses the product water outlet as the backwash inlet, while treating the feed inlet and concentrate/blowdown outlets as the lower and upper backwash outlets, respectively. Imagine if a water treatment enthusiast naturally assumes reverse osmosis membrane backwashing operates in this manner—they would inevitably conclude that reverse osmosis membrane backwashing causes backpressure on the membrane elements, thereby destroying the membrane structure.
To further reinforce this concept, let's outline the operational flow of ultrafiltration membrane systems—I don't believe I've ever shared this process separately before.
(II) Ultrafiltration Membrane System Operational Flow (Including Cleaning) (Primarily sourced from original Dow technical manuals)
(1) Overview of Ultrafiltration Membrane Systems
Ultrafiltration membranes typically operate in full-flow mode, significantly reducing energy consumption. They maintain constant permeate flow (constant flow control), causing the transmembrane pressure (TMP) to gradually increase during filtration. This necessitates periodic air-flushing assisted backwashing to control TMP buildup. Solid particles retained on the membrane surface are removed through periodic air scouring-assisted backwashing, which requires no chemical additives. This process prevents solid contaminants from depositing on the membrane surface. Contaminants adsorbed onto the membrane surface that cannot be removed by backwashing are eliminated via online Chemical Enhanced Backwashing (CEB). During chemical enhanced backwashing, a small amount of chemical agent is added to the backwash water. After a brief soak (typically 5–10 minutes), the chemical agent is flushed out, restoring the ultrafiltration membrane to near its initial state. Additionally, ultrafiltration membrane systems require periodic chemical cleaning in place (CIP) to thoroughly remove contaminants and restore membrane performance. CIP chemicals may include sodium hydroxide, sodium hypochlorite, hydrochloric acid, citric acid, etc.
(2) Ultrafiltration Membrane System Operation Steps
The operational steps for ultrafiltration membrane systems primarily include: filtration, air scouring, bottom drainage, top backwashing, bottom backwashing, forward flushing, chemical enhanced backwashing (CEB), and chemical cleaning in place (CIP).
① Filtration (Separation Mode)
Upon system startup, a 2-3 minute forward flush is recommended to remove residual chemicals and air from the membrane modules. During forward flush, feedwater enters through the bottom inlet, rinses the outer surface of the membrane fibers, and exits via the top concentrate outlet. No feedwater is filtered during this phase. After completion, the system transitions to filtration mode. A typical operating cycle lasts 20-60 minutes, varying based on feedwater conditions and cleaning protocols. During normal filtration, 100% of the feedwater is processed (full-flow filtration). As contaminants are retained, the transmembrane pressure (TMP) increases. At the end of the preset operating cycle, the system transitions to air scouring and backwashing cleaning steps.
② Air Scouring
The ultrafiltration membrane system automatically initiates the air scouring step. This process uses compressed air to generate bubbles that dislodge contaminants trapped on the outer surface of the membrane fibers. Compressed air enters through the bottom inlet of the membrane module, flows over the outer surface of the fibers, and exits through the top concentrate outlet.
③ Bottom Drainage
Following the air scouring step, air supply ceases. The bottom drain valve opens to gravity-drain the membrane module, carrying away loosened contaminants with the effluent.
④ Top Backwash
Upon completion of drainage, the first backwash step—top backwash—is initiated. Backwash water enters the membrane fibers through the top product water port, permeating in the opposite direction of operational product water flow. Backwash effluent accumulates externally on the membrane fibers. Opening the top backwash discharge valve allows effluent to exit via the membrane module's top concentrate port. This top backwash step prioritizes cleaning the most heavily contaminated upper region of the membrane module.
⑤ Downwash
The second backwash step, known as downwash, removes contaminants from the lower section of the membrane module. Maintain backwash water entry through the upper product water port. Open the downwash discharge valve to expel backwash wastewater through the lower feed port, effectively removing contaminants from the lower section.
⑥ Forward Flushing
After backwashing concludes, forward flushing is required to remove any residual contaminants and chemicals while purging air trapped within the membrane module. Upon completing forward flushing, the ultrafiltration system can be returned to filtration operation or standby status.
⑦Chemically Enhanced Backwashing (CEB)
When conventional air scouring-assisted backwashing fails to remove all contaminants, chemical agents can be added during backwashing to enhance its effectiveness—this is chemically enhanced backwashing (CEB).
The CEB process comprises an air scouring phase, chemical-added backwashing, soaking, and a conventional air scouring-assisted backwashing phase to flush out contaminants and chemicals.
Depending on the chemicals used, CEB is generally categorized into:
- Alkaline CEB: Targets contamination caused by organic matter and biological growth in feedwater.
- Acidic CEB: Addresses inorganic contamination from colloidal iron/aluminum or hardness scaling in feedwater.
Alkaline CEB: 0.1% NaOCl + 0.05% NaOH (target pH 12)
Acid CEB: 0.1% HCl or H₂SO₄ (target pH 2)
⑧ Chemical Cleaning in Place (CIP)
CIP operations comprise backwashing and chemical circulation cleaning. CIP frequency depends on feedwater quality, ranging from monthly to quarterly intervals. A routine backwash must be performed prior to CIP, comprising the following steps: air scouring, bottom blowdown, top backwash, and bottom backwash. The backwash sequence is typically repeated 3 to 8 times to remove various contaminants that cannot be eliminated by chemical cleaning alone.
Since ultrafiltration membrane systems operate with frequent backwashing (every 20 to 60 minutes), automated control is generally employed. Considering significant variations in feedwater quality across different systems, specific operating and cleaning parameters, as well as sequence steps, must be finalized based on on-site commissioning results. The general principle is to increase the frequency of backwashing, air scouring, and chemically enhanced backwashing when feedwater quality is poor.