Choosing a Reverse Osmosis Water Purifier: How to Interpret a Machine’s Performance from the Specifications Sheet
There are countless manufacturers and models of reverse osmosis (RO) water purifiers on the market today. High flow rates, high gallon ratings, long-lasting filter cartridges, integrated water pathways, Class
1 water efficiency—the array of selling points can be overwhelming.
Many consumers tend to base their purchasing decisions on manufacturers’ marketing claims, often overlooking the product specification sheets. It’s important to note that marketing claims are often embellished descriptions based on ideal laboratory conditions.
Only by understanding the specification sheet—as well as the testing conditions, system losses, and real-world water usage scenarios behind the numbers—can you clearly assess the true performance of an RO water purifier and avoid being misled by figures on paper.
Let’s break down the specification sheet for an RO water purifier.
1. Health Permit Number
According to the “Law on the Prevention and Control of Infectious Diseases” and the “Measures for the Supervision and Administration of Domestic Drinking Water Hygiene,” water purifiers produced, sold, or used in China must obtain a water-related permit issued by provincial-level health authorities.
Obtaining this permit indicates that, during normal use, the water purifier itself will not release toxic or harmful substances into drinking water, or that any such substances released will not exceed permissible limits. This confirms that its materials are safe and can be used with confidence in household water applications.
No matter how compelling the manufacturer’s or retailer’s sales pitch may be, or how extravagant their feature descriptions, we should not purchase machines without a water safety permit.
2. Membrane Flux
Membrane flux refers to the flow rate of the device’s RO membrane; it denotes the volume of water passing through a unit area of the reverse osmosis membrane per unit of time under specific operating conditions.
The unit is GPD (gallons per day), commonly abbreviated as “G.” Common membrane flux ratings for household use include 50G, 100G, 400G, 800G, 1000G, and so on.
1 gallon = 3.785 liters (Note: This is a U.S. liquid gallon; the domestic water purification industry exclusively uses U.S. liquid gallons.)
A flux of 50G means: 50 × 3.785 = 189.25 L/d = 7.9 L/h = 0.13 L/min.
A flux of 100G means: 100 × 3.785 = 378.5 L/d = 15.8 L/h = 0.26 L/min.
A flux of 400 G means: 400 × 3.785 = 1,514 L/d = 63.1 L/h = 1.05 L/min.
The theoretical flux for 800 G: 800 × 3.785 = 3,028 L/d = 126.2 L/h = 2.10 L/min.
Theoretical flux for 1000G: 1000 × 3.785 = 3785 L/d = 157.7 L/h = 2.63 L/min.
(Unit notes: L/d = liters per day; L/h = liters per hour; L/min = liters per minute)
The higher the gallon rating, the greater the membrane flux, and the greater the water flow rate of the entire water purification system.
Under laboratory test conditions—with the system’s pump pressure properly calibrated and the flow path designed optimally—the system’s theoretical flux will approach or equal the membrane flux.
Since national standards only specify “membrane flux” and do not define “system-level water purification flux,” many manufacturers or retailers, for marketing convenience, refer to the membrane’s GPD flux as the system’s water purification flux.
In actual use, however, operating conditions are far more complex than laboratory test conditions, so the discrepancy between the two values can be significant. This explains why, even when purchasing the same machine, the flow rate may perform well in some households but fall short of expectations in others.
3. Water Flow Rate
Water flow rate: The water output per unit of time as claimed by the manufacturer under standard test conditions. Units: liters per minute or liters per hour. In layman’s terms, this refers to the speed at which water flows from the faucet.
Water purifiers equipped with reverse osmosis membranes with a flux of 400G or higher, paired with a suitable built-in pump and flow channel design, have a high water-handling capacity and deliver a high flow rate from the faucet. As a result, they can operate without a storage tank—these are known as high-flux, tankless systems.
In contrast, water purifiers using low-flux membranes—such as 50G, 75G, or 100G—produce water more slowly. If the water were to flow directly from the faucet, the flow rate would be too slow, which would be frustrating for users. Therefore, these units are paired with a storage tank (typically 3 gallons, with an actual storage capacity of 6–8 liters). The water is produced in advance and stored in the tank, allowing for a flow rate of 2 liters per minute when dispensed—these are known as “low-flux tank-based systems.”
From a purchasing perspective, the water flow rate directly affects the speed at which water comes out of the faucet and is closely related to the user experience. This is an important factor to consider.
It is worth noting that the water flow rate listed on the product nameplate is a test result obtained under standard test conditions. In actual use, factors such as the quality and temperature of the incoming water, as well as pre-treatment stages upstream of the system, can cause the actual performance to differ from the rated specifications.
4. Rated Total Purified Water Volume
Definition of rated total purified water volume: The volume of water produced when the outlet water quality, removal efficiency, and purified water flow rate of a drinking water treatment device all meet requirements under standard test conditions. Unit: liters. *GB/T 30307-2023 Drinking Water Treatment Devices for Household and Similar Uses*.
In simple terms, the rated total purified water volume represents the maximum service life of one or all filter cartridges. Once the cumulative purified water volume reaches this value, the device’s effluent water quality, removal efficiency, or flow rate will begin to fall below standards, indicating that the filter cartridges need to be replaced.
In my opinion, the rated total purified water volume is one of the core metrics for selecting a reverse osmosis water purifier. A higher rated total purified water volume means that, under the same usage conditions, the filter cartridges will last longer, requiring fewer replacements and resulting in lower long-term operating costs.
It should be noted that the rated total water purification capacity is a value tested under standardized laboratory inlet water conditions. In actual home use, however, filter cartridge lifespan varies due to differences in household inlet water quality (such as regional differences, water source variations, and the presence of aging pipeline networks) and variations in pre-treatment equipment installed upstream of the system. As a result, the actual total purified water volume may deviate significantly from the rated total.
Furthermore, a high rated total water purification capacity does not equate to faster water output; it is unrelated to membrane flux or purified water flow rate. A machine with high flux may have a relatively low rated total water purification capacity if its overall performance is average, whereas a machine with low flux can achieve a very high rated total water purification capacity if its overall performance is excellent.
The market is flooded with countless manufacturers and models of reverse osmosis (RO) water purifiers, featuring selling points such as high flux, high gallon capacity, long-lasting filter cartridges, integrated water pathways, and first-class water efficiency—all of which can be overwhelming.
Many consumers tend to base their purchasing decisions on marketing claims, often overlooking the product specification sheet. It’s important to note that marketing claims typically describe performance under ideal laboratory conditions. Only by understanding the specification sheet—as well as the test conditions, system losses, and real-world usage scenarios behind the numbers—can you truly assess the actual performance of an RO water purifier and avoid being misled by figures on paper.
Let’s continue breaking down the specification sheet for RO water purifiers.
5. Water Efficiency Rating
Before discussing the water efficiency rating, let’s clarify three key concepts—pure water output, concentrate, and water recovery rate—to facilitate understanding.
Pure Water Output: Water that passes through the RO membrane and is ultimately dispensed from the purified water faucet.
Concentrate: Water produced after passing through the water purifier, which has increased salt content and is thus concentrated. Simply put, this is water that has not passed through the RO membrane; it is used to flush the membrane and is ultimately discharged. The industry refers to this as “wastewater.”
Total Inflow = Purified Water Output + Concentrate Water Output.
Pure Water Recovery Rate: Under specified test conditions, the ratio of the total volume of purified water produced by the water purifier to the total feed water volume. A higher pure water recovery rate indicates that the unit is more water-efficient.
Under standardized test conditions, the national standard classifies water purifiers into water efficiency grades. Units that meet both the recovery rate and the rated total purified water volume requirements are categorized into three grades. Units with a water efficiency grade lower than Grade 3 are prohibited from entering the market.
After all, water recovery rate and water efficiency ratings are theoretical data derived from laboratory tests. In areas with variable raw water quality—especially regions with high TDS levels and hardness—a high water recovery rate and low wastewater discharge mean a heavier workload on the membrane, leading to faster membrane wear. This is what industry insiders refer to as: “Save on water bills with the membrane, but preserve the membrane with wastewater.”
Therefore, my personal recommendation is not to overly pursue the water-saving benefits of high water recovery rates and high water efficiency ratings. Instead, you should consider the specific quality of your local incoming water and strike a balance between membrane lifespan and water-saving performance to select a machine suitable for your local water conditions.
6. Removal Efficiency
As mentioned above, the rated total purified water volume is one of the core metrics for evaluating water purifiers. Removal efficiency is just as important as the rated total purified water volume; it is also a core metric for evaluating reverse osmosis water purifiers. The rated total purified water volume reflects the long-term operating costs of the equipment and the actual service life of the filter cartridges; removal efficiency, on the other hand, is the metric that best reflects the overall filtration capacity of the unit.
Before discussing removal efficiency, let’s clarify two concepts: desalination rate and conductivity removal rate.
Desalination Rate: The ability to remove salts from the feed solution (GB 32373-2025 “Test Methods for Reverse Osmosis Membranes”). The desalination rate is experimental data reflecting the performance of a single membrane, not that of the entire system.
Conductivity removal rate, on the other hand, is the removal rate measured for a complete water purifier (including filter cartridges, piping, and various seals) using water simulating municipal tap water (in terms of composition, temperature, and water pressure) as the feed water, throughout the entire operational cycle—including flushing, water production, and shutdown. It not only assesses the quality of the membrane but also indirectly identifies any abnormalities in the entire water circulation system, seals, pump pressure, and other components.
Therefore, the desalination rate of a single membrane does not equate to the removal efficiency achieved by the entire unit after water flow. However, in many water purifier advertisements, the desalination rate is often mistakenly presented as the system’s overall removal rate—this is a point that requires special attention when making a purchase.
The removal efficiency of a qualified household reverse osmosis water purifier is determined by two metrics:
① Total hardness (expressed as calcium carbonate) removal rate ≥ 90%
② Removal rate of conductivity ≥ 85%.
Accurate removal rate measurements require a test report from a professional CAM-certified institution or the use of a specialized conductivity meter—both of which are costly. In daily use, a TDS pen (costing about ten yuan) can be used to test and estimate the removal rate—it’s inexpensive and convenient.
Example of calculating removal efficiency using a TDS pen:
If the raw water TDS value is 300 and the purified water TDS value is 30, the estimated removal efficiency is: (300 – 30) / 300 = 90%.
If the raw water TDS value is 300 and the purified water TDS value is 50, the estimated removal efficiency is: (300 – 50) / 300 = 83.3%.
Since readings taken at different pressures and temperatures may differ from those under standard conditions, data from the TDS pen should be used as a general reference rather than an absolute measure.
During long-term use, if TDS readings consistently fall below 85% and show a downward trend, this situation warrants attention, and you should consider servicing the equipment.
Summary
Health permit approval, membrane flux, purified water flow rate, rated total purified water volume, water efficiency rating, and removal rate are the six key indicators for evaluating a reverse osmosis water purifier.
Each of these six indicators serves a distinct purpose, corresponding respectively to regulatory compliance, membrane performance, user experience, operating costs, water-saving performance, and overall filtration effectiveness. No single indicator can independently determine the quality of the equipment; only by considering them comprehensively can one fully understand a reverse osmosis water purifier.